Numerical investigation of electro-conjugate fluid micro-pump under the effects of downstream angle and the negative electrode width

Author affiliations

Authors

  • Van Tran Do \(^1\) School of Mechanical Engineering, Hanoi University of Science and Technology, No. 1 Dai Co Viet, Hanoi, Vietnam
    \(^2\) Faculty of Mechanical Engineering, University of Transport and Communications, No. 3 Cau Giay, Hanoi, Vietnam
    https://orcid.org/0009-0007-2086-0891
  • The Khanh Lai \(^1\) School of Mechanical Engineering, Hanoi University of Science and Technology, No. 1 Dai Co Viet, Hanoi, Vietnam https://orcid.org/0009-0007-8293-0031
  • Toan Thang Vu \(^1\) School of Mechanical Engineering, Hanoi University of Science and Technology, No. 1 Dai Co Viet, Hanoi, Vietnam
  • Thi Anh Nguyen \(^3\) chool of Electrical and Electronic Engineering, Hanoi University of Science and Technology, No. 1 Dai Co Viet, Hanoi, Vietnam
  • Ich Long Ngo \(^1\) School of Mechanical Engineering, Hanoi University of Science and Technology, No. 1 Dai Co Viet Street, Hanoi, Vietnam https://orcid.org/0000-0003-2406-5725

DOI:

https://doi.org/10.15625/0866-7136/22383

Keywords:

electro-conjugate fluid, finite element method, micro-pump

Abstract

This paper describes a numerical study of the electro-hydrodynamic behaviors of the fluid flow in an electro-conjugate fluid (ECF) micro-pump under the effects of the collector electrode width (Lc) and its downstream angle (α2). The finite element method was used to examine the characteristics of the ECF micro-pump with the applied voltage ranging from 2 kV to 8 kV, Lc ranging from 0.0 to 4.0, and α2 ranging from 30º to 90º. Consequently, the numerical results indicated that the ECF flow characteristics and the operating ranges of this ECF micro-pump are affected significantly by α2 and Lc of the negative electrode. Indeed, the operating range of the ECF micro-pump can be further extended by reducing α2, particularly at higher flow rates. Moreover, the operating ranges of both pressure difference (∆p) and flow rate of the ECF micro-pump can be extended when Lc varies in the optimum range, i.e., from 0.5 to 2.0. The maximum efficiency of such an ECF micro-pump was 7.4% at φ0 = 8 kV and Lc = 2.0. These results play a critical role in understanding the electro-hydrodynamic behaviors of the fluid flow in an ECF micro-pump, and they can be applied in mechanical and biomedical engineering fields.

Downloads

Download data is not yet available.

References

[1] R.-J. Yang, H.-H. Hou, Y.-N. Wang, and L.-M. Fu. Micro-magnetofluidics in microfluidic systems: A review. Sensors and Actuators B: Chemical, 224, (2016), pp. 1–15. https://doi.org/10.1016/j.snb.2015.10.053.

[2] Z. Mao, T. Nagaoka, S. Yokota, and J.-W. Kim. Soft fiber-reinforced bending finger with three chambers actuated by ECF (electro-conjugate fluid) pumps. Sensors and Actuators A: Physical, 310, (2020). https://doi.org/10.1016/j.sna.2020.112034.

[3] S. Mohith, P. N. Karanth, and S. M. Kulkarni. Recent trends in mechanical micropumps and their applications: A review. Mechatronics, 60, (2019), pp. 34–55. https://doi.org/10.1016/j.mechatronics.2019.04.009.

[4] Y.-N. Wang and L.-M. Fu. Micropumps and biomedical applications – a review. Microelectronic Engineering, 195, (2018), pp. 121–138. https://doi.org/10.1016/j.mee.2018.04.008.

[5] K. Edamura, Y. Ohashi, and S. Yokota. The use of electro-sensitive movable fluids, methods of using the same and motors for the electro-sensitive movable fluids, (2002). European Patent.

[6] K. Mori, H. Yamamoto, K. Takemura, S. Yokota, and K. Edamura. Dominant factors inducing electro-conjugate fluid flow. Sensors and Actuators A: Physical, 167, (1), (2011), pp. 84–90. https://doi.org/10.1016/j.sna.2011.01.009.

[7] V. Cacucciolo, J. Shintake, Y. Kuwajima, S. Maeda, D. Floreano, and H. Shea. Stretchable pumps for soft machines. Nature, 572, (7770), (2019), pp. 516–519. https://doi.org/10.1038/s41586-019-1479-6.

[8] H. Sun, J. Zhao, Y. Zhang, and M. Xu. Flexible pump for small-scale soft robotics: actuation, design and prospects. Measurement, 237, (2024). https://doi.org/10.1016/j.measurement.2024.115299.

[9] T. Matsubara, H. H. Huynh, K. Yoshida, and J.-W. Kim. Development of MEMS-fabricated bidirectional ECF (electro-conjugate fluid) micropumps. Sensors and Actuators A: Physical, 295, (2019), pp. 317–323. https://doi.org/10.1016/j.sna.2019.06.022.

[10] S. Ueno, K. Takemura, S. Yokota, and K. Edamura. Micro inchworm robot using electro-conjugate fluid. Sensors and Actuators A: Physical, 216, (2014), pp. 36–42. https://doi.org/10.1016/j.sna.2014.04.032.

[11] J.-W. Kim, T. Suzuki, S. Yokota, and K. Edamura. Tube-type micropump by using electro-conjugated fluid (ECF). Sensors and Actuators A: Physical, 174, (2012), pp. 155–161. https://doi.org/10.1016/j.sna.2011.10.027.

[12] J.-W. Kim, Y. Yamada, and S. Yokota. Micro ECF (electro-conjugate fluid) hydraulic power sources based on the modular design of TPSEs (triangular prism and slit electrode pairs). The International Journal of Advanced Manufacturing Technology, 106, (1-2), (2020), pp. 627–639. https://doi.org/10.1007/s00170-019-04598-x.

[13] S. Yokota, K. Kawamura, K. Takemura, and K. Edamura. High-integration micromotor using electro-conjugate fluid (ECF). Journal of Robotics and Mechatronics, 17, (2), (2005), pp. 142–148. https://doi.org/10.20965/jrm.2005.p0142.

[14] T. Otomo, T. Matsubara, K. Yoshida, D.-H. Kim, M. Ikeuchi, and J.-W. Kim. A microfluidic device integrated with a stretchable microporous membrane controlled by electro-conjugate fluid. Sensors and Actuators A: Physical, 356, (2023). https://doi.org/10.1016/j.sna.2023.114332.

[15] Y. Kuroboshi, K. Takemura, and K. Edamura. Efficient electrode configuration for electro-conjugate fluid flow generation with dibutyl decanedioate: Experimental and theoretical investigation. Sensors and Actuators A: Physical, 279, (2018), pp. 223–228. https://doi.org/10.1016/j.sna.2018.06.018.

[16] W.-S. Seo, K. Yoshida, S. Yokota, and K. Edamura. A high performance planar pump using electro-conjugate fluid with improved electrode patterns. Sensors and Actuators A: Physical, 134, (2), (2007), pp. 606–614. https://doi.org/10.1016/j.sna.2006.06.027.

[17] R. V. Raghavan, J. Qu, L. Y. Yeo, J. R. Friend, K. Takemura, S. Yokota, and K. Edamura. Electrokinetic actuation of low conductivity dielectric liquids. Sensors and Actuators B: Chemical, 140, (1), (2009), pp. 287–294. https://doi.org/10.1016/j.snb.2009.04.020.

[18] D. Han, H. Wang, S. Yokota, and J.-W. Kim. Configurations of triangular prism and slit electrode pairs to enhance the performance of electro-conjugate fluid micropumps. Journal of Micromechanics and Microengineering, 30, (2), (2020). https://doi.org/10.1088/1361-6439/ab5ef3.

[19] T. K. Lai, T. Dinh, M. D. Nguyen, and I. L. Ngo. A new design of electro-conjugate fluid micropumps with Venturi and teardrop-shaped electrodes. Physics of Fluids, 36, (9), (2024). https://doi.org/10.1063/5.0221203.

[20] H. C. Chang and L. Y. Yeo. Electrokinetically driven microfluidics and nanofluidics. Cambridge University Press, New York, (2010).

[21] W. K. H. Panofsky and M. Phillips. Classical Electricity and Magnetism. Addison-Wesley Publishing Company, Cambridge, MA, (1961).

[22] K. D. Tran, Y. Kikuchi, and H. Yanada. Measurement and numerical simulation of flow and electric fields in charge injection type of electrostatic oil filter. Transactions of the Japan Fluid Power System Society, 40, (1), (2009), pp. 8–15. https://doi.org/10.5739/jfps.40.8.

[23] M. Nishikawara, M. Shimada, M. Saigo, and H. Yanada. Numerical investigation of the characteristics of an ion drag pump. Journal of Electrostatics, 84, (2016), pp. 23–31. https://doi.org/10.1016/j.elstat.2016.08.001.

[24] H. Yanada, S. Hakama, T. Miyashita, and N. Zhang. An investigation of an ion drag pump using a needle-mesh electrode configuration. Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, 216, (3), (2002), pp. 325–334. https://doi.org/10.1243/0954406021525034.

F7a

Downloads

Published

09-08-2025

How to Cite

Do, V. T., Lai, T. K., Vu, T. T., Nguyen, T. A., & Ngo, I. L. (2025). Numerical investigation of electro-conjugate fluid micro-pump under the effects of downstream angle and the negative electrode width. Vietnam Journal of Mechanics, 47(3), 259–274. https://doi.org/10.15625/0866-7136/22383

Issue

Section

Research Article

Categories

Funding data

Similar Articles

<< < 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 > >> 

You may also start an advanced similarity search for this article.